Penetrant testing

With the Penetrant Testing procedure (also known as DP test or dye penetrant inspection) you can quickly determine surface discontinuities on all iron metals and non-iron metals, some plastics and ceramic materials, glass, etc., provided that the discontinuities are open to the surfaces. 

The liquid penetrant test method is used in the examination of welding seams, cast pieces, in shipbuilding, automobile and aircraft construction, apparatus and tank construction, etc. 

Liquid penetrant inspection can be carried out with at daylight visible (red dye penetrant) and/or under UV-light fluorescent penetrants. 

The PT method is charactestic for the fact that, contrary to the magnetic particle inspection (MT), defects or discontinuities can be proven also on not magnetizable materials.

Product Details
Brand :
Place of Origin : Not Given
FOB Price :
Minimum Order Quantity : Not Given
Supply Ability :
     
Packaging & Delivery
Packaging Detail : International Standard Packaging 
Delivery Detail : ASAP
Specifications

The testing procedure consists of four separate processing steps, for which the following products are necessary:

  1. Precleaning ( Remover)
  2. Application of penetrant ( Penetrant)
  3. Excess penetrant removal ( Remover or water)
  4. Application of developer ( Deve